Configure the inputs in digital or analogue mode

    Control inputs remotely

    READ MORE
    Configure logical names for easy recognition

    Control inputs remotely

    READ MORE
    Create your own notifications

    Control inputs remotely

    READ MORE

    GSM Modules with Universal Inputs

    Depending on the source the input of the GSM-PRO2 can operate in digital or analogue mode. This gives maximum flexibility during the development process. In case of a change in signal type, an input can be easily changed from digital to analogue mode or vice versa. Give each input a clear name for easy recognition. This will be shown in all applications. For each individual input contact(s) created, you can select whomever to receive a message via per SMS, e-mail or by a phone call. In the CONTA-SUPERVISION  IoT portal and App, a message will be displayed shortly and will be moved to the event list.

    UNIVERSAL INPUT | DIGITAL

    When a GSM-PRO2 I/O module input is operating in digital mode then a message can be sent at each time a flank changes. When the voltage is higher then 6 Vdc and lower then 30 Vdc then the I/O module will recognise this as 1 and if the voltage is between 0 Vdc and 3 Vdc then this is a 0. A message can be sent straight away or a delay can be configured. The text of the message can be freely chosen for a raising or falling flank, if needed a date and time stamp, input name and module name can be added to the text as well. Each input has its own operating hour counter. In the CONTA-SUPERVISION IoT portal/App the inputs will be shown visually and messages are added in the event list.

    UNIVERSAL INPUT | ANALOGUE

    The analogue input of the GSM-PRO I/O module can be set in voltage (0V – 10 V) or current (0mA – 20 mA). The module is able to send a message on three points. When the signal crosses from normal to upper, from normal to lower and from upper/lower level to normal the module is able to send a message. For each threshold value an own text can be defined. A delay or minimum level change can be configured before the I/O module sends a message. This is useful when sloshing liquid is measured. The minimum level change prevents incorrect messages. In the CONTA-SUPERVISION IoT portal/App the inputs will be real-time shown visually and messages are added in the event list.

    UNIVERSAL INPUTS | CONFIRMATION SEQUENCE

    When the confirmation sequence is active then a message will be sent to the chosen contacts. The message can be stopped by using a predefined stop command or when the maximum sequences is reached.

    UNIVERSAL INPUTS | ANALOGUE (log function)

    The analogue inputs have the ability to log the input in 6 time intervals from 10 minutes up to 60 minutes.

    UNIVERSAL INPUTS | NOTICIFICATIONS

    When a signal is detected notifications will be shown in the CONTA-SUPERVISON IoT Portal/App, GSM-PRO2 App and text and e-mail messages can be sent and a phone call can be started.

    MORE INFORMATION?

    Call us at +31 495 566 046 or fill in the contact form.